VARIOUS
TESTING INSTRUMENTS
1
2 NEXT |
 |
JIA-PP information
PUSH PULL GAUGE
It's used for testing tensile, compression and push
strength.
Model: JIA-PP JIA-FG
Indicator: dial gauge LCD
Capacity: 1∼50㎏ 2,5,20,50㎏ (optional) (optional)
Unit: ㎏、N ㎏,N,lB by spectable
Accuracy: ±0.5﹪ ±0.2﹪
Resolution: 1/200
|
 |
JIA-GS information
HARDNESS TESTER
ASTM-2240A
Measure the hardness of rubber......etc.
Model:GS-701(C)SRIS-0101 GS-702(D)SHORE
D GS-706(JA)jiS-k6301A GS-709(A)astm D-2240A
ASKER-C SRIS-0101
|
 |
JIA-GS710 information
HARDNESS CONSTANT PRESSURE WEIGHING
It's used to furnish the bass for hardness tester to
retain the accurate, steady and unform forcing angle
to the specimen, and avoid test errors due to uneven
surface of it.
Load:5㎏
Specimen pan:70 ㎜
|
 |
JIA-SM information
THICKNESS GAUGE
Measure the thickness of rubber, fabric, paper,
......etc.
Model:SM-112、SM114
Test range:0.01∼10㎜
Test depth:20㎜、120㎜
|
|
|
|
 |
JIA-GH information
DESKTOP THICKNESS GAUGE
Measure specimen's thickness.
Test range:0.01∼10㎜
Measuring deoth:45㎜
Compression of test:550g/㎝
|
 |
CENTER-300 information
MULTI-FUNCTIONAL DIGITAL THERMOMETER
This meter is to measure the temperature of various
material.
Test range:-160∼+1372℃
Accuracy:199℃以下0.1℃ 200℃ UP 1℃00
|
 |
JIA-FD information
INFRARED MOISTURE METER
Test range:0∼100%
Indication:0.2∼20%
Test weight:2.5g∼10g
|
 |
JIA-JK information
PRECISION BALANCES
Capacity:210g
Accuracy:0.1g 0.01g 0.001g 0.1mg
|
|
|
|
 |
JIA-MP1D information
PH METER
Model:electronic type of digits
Temp.: room temp.∼400℃
Accuracy:±1℃
Control: P.I.D, LED The same time of test 3pcs/time
Temp. up
speed:400℃/20min
|
 |
JIA-5601 information
MOISTURE METER
Test range:0∼100﹪Accuracy:0.1﹪Indicator:LED
display
|
 |
CENTER-310 information
THERMO -HYGROMETER
Test range:Temperature -15∼60℃
Humid. 5∼98﹪RH
Accuracy:Temperature ±0.2℃ Humid. ±2.5﹪RH
Selectable ℃/°F readingLED display
|
 |
JIA-TH information
TABLETS HARDNESS TESTER USP
Capacity:0∼20㎏
Accuracy:0.1㎏(100g)
|
|
|
|
 |
JIA-ST information
NONCONTACT TEMPERATURE MEASUREMENT
Model:ST2、ST3
Temp.:-32∼400℃
Accuracy:±1℃
D: S: 8 : 1
|
 |
JIA-211 information
ELECTRONIC WIND SPEED INDICATOR
Wind speed of unit:m/s 0∼44.8FPMX100
0∼8790MPH 0∼99.9 (optional)
|
 |
JIA-EE1 information
TACHOMETERS
Model:EE1、EE2Test range:EE1(1∼25,000R.P.M)
EE2(6∼30,000R.P.M)
Test unit :rpm, m/min
Accuracy:EE1 1∼5,999±1rpm 6,000∼25,000±2rpm EE2
6∼5,999±1rpm 6,000∼30,000±3rpm
|
 |
JIA-CD information
PRECISION DIAL TORQUE WRENCH
Model:CD-301LDIN
Test range:0∼30 IN/LB 、0∼35㎝/㎏
Accuracy:0.5IN/LB、1㎝/㎏
|
|
1
2 NEXT |
|
|
|
|