BIG PICTURE


JIA-621CORD WINDING CRACK TESTER

If the cross sectional area of conductor is less than 100mm². Then specimen must be into testing chamber for freezing for one hour, after that immediately roll specimen around the circular rod of which diameter is specified in uniform speed. Otherwise, the cross sectional area is beyond 100mm². Then specimen firstly be rolled into a circular & put into chamber for freezing one hour. Afterwards, immediately roll specimen around the rod by opposite direction. Finally, take out of specimen for checking weather its surface has crack or fissure or not.

SpecSpec:

Temp.

-50℃

Cooling Method

 Air Frozen

Cooling Speed

Regular temp.~-40℃, 60min

Accuracy

±1℃

Material

SUS304#

Rod

4rods, 1.5~2times the thickness of specimen

Test Chamber

40X40X50㎝

Motor

450WX2

Dimension

130X60X76㎝     (WXDXH)

Weight

 135 kg

 Power

220V/50Hz

Justice Testing Instruments Co,.Ltd. Tel:886-4-22600576   886-4-22658816;Fax:886-4-22635697